pressure(MPa)壓力(MPa) 0.02 0.05 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Average flow rate(L/min)流量平均值(L/min) 3 5 8 10 13 15 17 19 22 25
Instructions 使用說明
Rated voltage 額定電壓  脈衝6V/DC9V/DC12V/DC24V/DC36V/DC48V/DC110V/AC12V/AC24V/AC36V/AC48V/AC110V/AC220V
Coil resistance 線圈電阻 12.8Ω±10%(20℃)26Ω±10%(20℃)41Ω±10%(20℃)125Ω±10%(20℃) 287Ω±10%(20℃)410Ω±10%(20℃)3KΩ±10%(20℃)26Ω±10%(20℃) 76Ω±10%(20℃) 128Ω±10%(20℃)234Ω±10%(20℃)1300Ω±10%(20℃) 4.75KΩ±10%(20℃) 
Min Current 最低電流 228mA
Switch mode 開關型式  Direct Current Pulse
Pulse Width 脈衝寬度 ≥30ms
Operating pressure 工作壓力  0-0.05Mpa
Medium temperature 介質溫度  1℃-50℃
Responding time 響應時間 open≤0.15s  close≤0.5s   開≤0.15s   關≤0.5s

Performance test 性能試驗

The Strength test 強度試驗 Static pressure 1.2Mpa 靜壓 1.2Mpa withstand voltage pressure耐水壓 1.2Mpa/5min
No load test空載測試 voltage V*0.9(電壓)  permission limiting voltage 允許限壓(電壓)     V*1.15
High water pressure start and closeing
高水壓啟動與關閉
At water pressure 0.8Mpa, voltage V*0.9,  the solenoid valve can be started and closed normally
水壓0.8Mpa, 電壓V*0.9,電磁閥能正常啟動與關閉
Low water pressure start and close
低水壓啟動與關閉
At water pressure 0.02Mpa, voltage V*0.9,  the solenoid valve can be started and closed normally
水壓0.02Mpa, 電壓V*0.9,電磁閥能正常啟動與關閉
Leakage High water pressure
高水壓泄露量
1.2Mpa zero leakage 1.2Mpa無泄露
Leakage High water pressure
低水壓泄露量
0.02Mpa leakage ≤0.1mL/min  0.03Mpa泄露量≤0.1mL/min
electric strength 
電氣強度
Among The conductive part,mounting hole and nonconductive metal,it can withstand Ac 1500V/50Hz, leakage current 0.75mA, for 1min without no two breakdown
導電部分與安裝孔及非導電金屬之間應能承受AC1500V/50Hz,漏電電流0.75mA,1min耐壓二無擊穿現象
Insulation resistance
絕緣電阻
the resistance between the charged part and nonconductive metallic part tested by the megohmmeter of 500v ≥20MΩ
用500V兆歐表測試導電部分與非導電金屬之間的電阻≥100MΩ
Sealing test 密封試驗 Static pressure 靜壓 air 空氣 high pressure 高壓 1MPa
Low pressure 低壓 0.02MPa
cold water 冷水 high pressure 高壓 1.2MPa
Low pressure 低壓 0.02MPa
Hot water 熱水 high pressure 高壓 0.8MPa
Low pressure 低壓 0.02MPa
Life test 使用壽命試驗 ≥Min 1,000,000 cycles (CJ/t 194-2004)  ≥1,000,000周期;符合CJ/T 194-2004要求


Working environment requirements 工作環境要求


Temp of Working environment
工作環境溫度
1℃~+50℃ permissible limiting pressureb 
(Water pressure)
允許限壓(水壓)
≤1.2Mpa
humidity Working environment
工作環境濕度 
35%~90%RH(No condensation state)  
35%~90%RH(無結露狀態)
mounting direction
安裝方向
it is mounted in Vertical direction, the inclination doesn't exceed 15 degrees
垂直方向,傾斜度不超過15度
Storage temp
保存溫度
-5~+80℃(No freezing state)
-5~+80℃(無結冰狀態)
Storage humidity
保存濕度
25%~95%RH(No condensation state)
25%~95%RH(無結露狀態)

Non-return function

止回功能

No

Adiustment function 

 調節功能

No

Filtering function  

過濾功能

No

Angle between coil and valve body   

線圈於閥體的角度

 360、270、180、90、0 

Power supply connection  

電源連接方式
插片 

Install spacing

安裝間距

No